Enviro DV50DX owner manual Operating Instructions, To Turn Gas Fireplace Off

Models: DV50DX

1 36
Download 36 pages 17.96 Kb
Page 8
Image 8
TO TURN GAS FIREPLACE OFF
Figure 5. Control Panel

Operating Instructions

BURNER LIGHTING:

A)Make sure the pilot is lit.

B)Turn gas control knob COUNTER CLOCKWISE to ON.

C)Flip the burner switch to ON.

D)Turn HI/LO knob to the desired flame height.

E)Turn on all electrical power to the unit.

NOTE: Check that all burner holes are lit.

TO TURN GAS FIREPLACE OFF

Flip switch to OFF to turn off burners only.

If the fireplace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. DO NOT

FORCE IT. If the unit is going to be serviced, turn off the electrical power to the unit as well.

NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for the first four (4) hours. This will cure the paint, logs, gasket material, and other products used in the manufacturing process. It is advised that a door or window be opened as the unit will start to smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See MAINTENANCE AND SERVICE - CLEANING THE

GLASS and MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL.

REMOTE CONTROLS:

This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall thermostat for operation guidelines.

AIR DIVERTER CONTROL:

When the blower is on, the amount of air flow into the room can be adjusted with the air diverter. When the lever is to the far left the room receives the air, when the lever is to the far right the air goes out the duct and when the lever in the middle the air goes to both the duct and the room. Lever is found above the right end of the control panel, see Figure 6.

BLOWER SPEED:

Figure 6. Air Diverter

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE until it “clicks” off (Figure 7).

It is advisable not to operate the blower below 1/3 speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.

��

���Manual background

��

Figure 7. Fan

Control

8

Page 8
Image 8
Enviro DV50DX owner manual Operating Instructions, To Turn Gas Fireplace Off