HORIZONTAL EXHAUST THROUGH WALL INSTALLATION - FREESTANDING:

Vent installation: install vent at clearances specified by the vent manufacturer.

A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and Equipment. Only use venting of L or PL type with an inside diameter of 3 or 4 inches (7.6 or 10.1 cm).

1.

Choose a location for your stove that meets the requirements stated in this manual and allows

 

installation with the least amount of interference to house framing, plumbing, wiring, etc.

2.

Install a non-combustible hearth pad (where necessary).

 

 

3. Place the appliance 15” (37.5 cm)

 

 

Wall

 

away from the wall. If the stove is

 

 

 

to be set on a hearth pad, set the

 

2"

thimble

 

unit on it.

 

 

 

 

 

 

(5 cm)

12"

 

 

 

 

 

 

 

 

4.

Locate the center of the exhaust

 

 

(30.5 cm)

 

pipe on the stove. Extend that line

 

 

45°

 

to the wall. Once you have located

 

 

 

 

 

elbow

 

the center point on the wall, refer to

 

 

 

 

pellet vent manufacturer installation

 

 

 

 

instructions for correct hole size and

6"

 

 

 

clearance to combustibles.

 

 

Rodent

5.

Install the wall thimble as per the

(15 cm)

 

mesh cap

 

instructions written on the thimble.

 

 

Fresh air

 

Maintain an effective vapour barrier

 

 

intake

 

in accordance with local building

 

 

 

 

codes.

 

 

 

 

 

Non-combustible

Existing floor

 

6.

Install a length of 3” (76 mm) or

 

floor protection.

(combustible)

 

 

4” (101 mm) vent pipe into the

 

 

 

 

 

 

wall thimble. The pipe should

Figure 21: Straight through wall Installation.

 

install

easily

into

the

 

 

 

 

 

thimble.

 

 

 

 

 

 

 

 

7.

Install

the

fresh

air

 

 

 

 

 

intake

(see

OUTSIDE

 

 

 

 

 

FRESH AIR CONNECTION).

 

 

 

 

8.

Connect

the

exhaust

 

 

Exhaust Tube

 

 

vent

 

pipe

 

to

the

 

 

3" (75mm) or 4" (100mm) "PL" or "L" vent

 

exhaust

 

pipe

on

 

 

 

 

 

 

 

 

 

the

stove.

Seal

the

 

 

Wall Thimble

 

connection

with

high

 

 

 

 

 

temperature silicone.

 

 

 

 

9.

Push the stove straight

 

 

 

45° Elbow with screen or

 

back,

 

leaving

a

 

 

 

 

 

 

 

 

Termination Cap

 

minimum of 2” (5 cm)

 

 

 

 

 

 

 

 

 

clearance

 

from

the

 

 

 

 

 

back of the stove to

Fresh Air Intake

 

 

 

the wall. Seal the vent

 

 

 

pipe

 

to

the

thimble

 

High Temperature RTV

 

 

 

 

Silicone Required

 

 

with high temperature

Figure 22: Venting to use with straight through wall Installation.

 

silicone.

 

 

 

 