Enviro EF-119 owner manual Troubleshooting, Do Not, What To Do If, The stove will not start

Models: EF-119

1 39
Download 39 pages 20.59 Kb
Page 27
Image 27
Troubleshooting

Troubleshooting

DO NOT:

wSwitch the stove On and OFF rapidly. This may cause current spikes, which could shorten the life of the electrical components.

wService the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures.

wRemove any screws in the firebox without first lubricating them with penetrating oil.

WHAT TO DO IF:

1.The stove will not start.

2.The stove will not light

3.The stove will not function in the “AUTO” mode when hot.

4.The exhaust blower will not function normally.

5.The convection blower will not function normally.

6.Everything else in the stove operates but the ignitor will not light the pellets

7.The auger motor does not function normally.

8.The Dial-A-Fire has no effect on the fire.

9.The stove will not shut off.

10.The stove keeps going out.

*NOTE: All troubleshooting procedures should be carried out by qualified technicians or installers.

1. The stove will not start.

wMake sure the stove is plugged in and the wall outlet is supplying power.

wPush the AUTO/MANUAL switch to MANUAL. If the stove fails to start, unplug the unit and open the hinged side panels (held tight with (2) two screws).

wWith the stove unplugged, examine all connections. Make sure they are firmly connected and that there are no exposed wires touching the stove (except the green chassis ground wire).

wCheck the continuity and placement of connections against the Wiring Diagram in this manual.

wAttempt to bypass the switch by inserting a jumper wire between the dual black wires (middle of the switch) and the single grey wire (left side of the stove) that attach to the back of the switch. Plug the stove back in. If the stove starts, replace the switch.

2. The stove will not light

wCheck the ignitor by removing the burn pot liner when the unit is cold.

wPush the AUTO/MANUAL switch to MANUAL.

wObserve the ignitor in the small tube to see if it glows within three (3) minutes then return the switch to the “AUTO” position.

wIf the ignitor does not come on, open the right hand side panel, remove the convection blower (held in by two (2) bolts) and check connections of the harness then by-pass the 120°F (49°C) (N/C) temperature sensor.

wPush switch to manual to see if the ignitor will heat up.

wIf the ignitor fails to come on, have your dealer or a qualified service technician replace the ignitor.

wIf the ignitor comes on when the 120°F (49°C) is by-passed, replace the 120°F (49°C) (N/C) sensor.

27

Page 27
Image 27
Enviro EF-119 owner manual Troubleshooting, Do Not, What To Do If, The stove will not start, The stove will not light