PARTS AND ACCESSORIES
Service Parts available from your local Envirogas Dealer
Burner Control Assembly | Convection Blower |
Natural Gas Pilot Assembly | Light Bulb Holder |
Propane Pilot Assembly | Light Switch (momentary) |
Door Bolt | Fan Controller |
Relief Door Gasket | Log Set (with Embers) |
Regulating Valve | Thermocouple |
Piezo Igniter | Embers |
Burner Switch | Thermopile |
Door Gasket | |
Orifice Blank | Convection Fan Sensor 120° (48°C) |
Accessories
Gold trim Package
Low Voltage Thermostat
REMOVING or INSTALLATION OF THE BLOWER
1. Turn the unit off and remove the log set.
2.Remove the burner tray assembly by removing the screw on either side of the tray, between the front and rear burners. Lift the tray out
3.Remove the
4.Carefully pull the assembly into the firebox.
Install the blower onto the mounting bracket (blower outlets pointing through the two holes in the bracket) using the 4 screws provided.
5.Connect wires according to the wiring diagram. (If removing the blower, disconnect the blower leads from the harness. Remove the blower.)
6.Check mounting plate gasket and reverse
steps 1 through 4.