Signal | Return |
|
|
|
Pin | Pin | Signal | Direction | Deccriptlon |
|
|
|
|
|
11 | 29 | BUSY | OUT | A HIGH signal Indicates the |
|
|
|
| printer cannot receive data. |
|
|
|
| The signal goes HIGH in the |
|
|
|
| following cases: |
|
|
|
| 1) During data entry (for each |
|
|
|
| character) |
|
|
|
| 2) During printlng |
|
|
|
| 3) When the Pause button is |
|
|
|
| pressed |
|
|
|
| 4) During an errar state |
|
|
|
|
|
12 | 30 | PE | OUT | A HIGH signal indicates that |
|
|
|
| the printer is out of paper. |
|
|
|
|
|
13 | - | SLCT | OUT | Pulled up to 5 V through |
|
|
|
| 1 .O kQ resistance |
|
|
|
|
|
14 | - | AUTO | IN | When this signal is LOW, the |
|
| FEED |
| paper b automatically fed |
|
| E |
| one line after printing. |
|
|
|
|
|
15 | - | NC |
| Not used |
|
|
|
|
|
16 | - | GND |
| Logic ground level |
|
|
|
|
|
17 | - | CHASSIS | - | Printer’s chassis ground, |
|
| GND |
| which is isolated from the |
|
|
|
| logic ground |
|
|
|
|
|
18 | - | NC |
| Not used |
|
|
|
|
|
- | GND |
| ||
|
|
|
| ground level |
|
|
|
|
|
31 | 16 | KiT | IN | When this level becomes |
|
|
|
| LOW, the printer controller is |
|
|
|
| reset to its state when the |
|
|
|
| power ls first turned on and |
|
|
|
| the print buffer Is cleared. |
|
|
|
| This level& normally HIGH; Its |
|
|
|
| pulse width must be more |
|
|
|
| than 50 us at the receiving |
|
|
|
| terminal. |
|
|
|
|
|