39. (1B, 6C, n)H (27,108, n)D, (9B, EC, n)H (155, 236, n)D

This code sets the left margin, The n selects the column with the present character width as the base. This code is ignored if the value of n exceeds a single line. This code clears the print data input already and the horizontal tabs..

If the left and right margins overlap, the one input first is considered valid

Page Length Setting Commands

The length of the page at power-on is selected by the FORM switch.

The following two codes, 40 and 41, are valid only when the FORM switch is set to ”0”,

40.(1B, 43, n)H (27, 67, n)D, (9B, C3, n)H (155, 195, n)D1 n [ 127. If n [ 128, this is ignored.

This code selects the page length in line units. The n is the line number. The length of a page is set by multiplying n by the present line-feed setting for a line. The maximum length of a page allowed to be set is 91 inches.

The paper position at the time this command is performed becomes the head of the first page. The page length will not change even if a line-feed amount is altered.

41.(1B, 43, 00, n)H (27, 67, 0, n)D, (9B, C3, 00, n)H (155,195, 0, n)D

1[ n [ 22. When n m 23 or n = 0, this is ignored. This code sets the page length in inches. The n is the number of inches,

Vertical Tab Commands

42. (1B, 42, n1, n2, .... nk, 00)H (27, 66, n1,

n2, .... nk, 0)D, (9B, C2, n1, n2, .... nk, 00)H (155, 194, n1, n2, .... nk, 00)D

This code sets the vertical tab positions. The n selects the number of lines. The vertical tab is positioned by multiplying the present single line-feed setting for a line by the set number of lines, The vertical tabs are set in sequence, with the smallest set

first. The code sequence ends with thecode.
A vertical tab is also automatically set at the head of the page

43.

(1B, 62, m, n1, n2, .... nk, 00)H (27, 98,

m, n1, n2, .... nk, 0)D, (9B, E2, m, n1, n2, .... nk, 00)H (155, 226, m, n1, n2,

.... nk, 0)D

0 [ m [ 7. This code sequence set the vertical tabs per channel. The m specifies the

channel. When m = 0, this code becomes the same as the code. The method of setting is the same as is done with

45