Sub Menu Function
DVI/HDMI Vi deo Range When the DVI-D or the HDMI input port are connected to a DVD player, set the video level according to the video level setting of the
DVD player. When HDMI is selected for the input source and the range is set to Auto
*3
, the video level of the input signal will be
automatically determined. If the range is set to Auto and the image shows whiteout or blackout, set the video level according to the video
level setting of the DVD player. The video level of the DVD player may be set to Normal or Expanded.
Input Signal You can select the input signal from the Computer1 input port or BNC input port.
If Auto is set, the input signal is identified automatically according to the connected equipment.
If colors do not appear correctly when this is set to Auto, select the appropriate signal according to the connected equipment.
Video Signal You can select the input signal from the Video1 input port, Video2 input port, and S-Video input port. If set to Auto, video signals are
recognized automatically. If interference appears in the image or a problem occurs such as no image is being projected when set to Auto,
select the appropriate signal according to the connected equipment.
Aspect You can set the Aspect Ratio
g
for projected images. s p.27
Overscan
*2
You can change the Output Scaling (the range of projected image). The range of trimming screen can be set to Off, 4%, or 8%. You can
select Auto
*3
only when the input source is HDMI. When Auto is selected, the range is automatically switched to Off or 8% according to
the input signal.
2-2 Pull-down
*2
This can be set only when 1080p/24Hz signals are being input. If this is set to On, images recorded 24 frames per second such as movies are
projected by original frame rate without frame interpolation. It is possible to recreate the natural feel of the original image.
Reset You can reset all adjustment values on the Signal menu to their default settings, except for Input Signal.
To return all menu items to their default settings, see s p.76
*1 When a component video or RGB video signals are input, this setting can be set only when 480i, 576i, or 1080i signals are being input.
*2 This cannot be set when a digital RGB signal is input.
*3 This can be set only when the HDMI output on the connected equipment is connected to the HDMI input port on the projector.
*4 This cannot be set when inputing 1080i signal and the aspect mode is set to Full.
Signal Menu54