Cause Step Checkpoint Finding Solution
The interlock switch lever is
bad. 1Does the switch turn on when
the case is closed? No Replace the interlock
lever.
The interlock switch may be
dead. 2Does the switch toggle?
(Check with a multimeter.) No Replace the interlock
switch.
The PWB-E board may be
dead. 3
With power on, is there an
output of +24 VDC between
pin 1 (+) and pin 2 (–) for
CN207 on C169 MAIN-B
board?
No
Replace the PWB-E
board.
The paper take-up sensor flag
position may be incorrect. 4Is the paper take-up sensor
flag position OK? No Reposition the paper
take-up sensor flag.
The paper exit sensor flag
position may be incorrect. 5Is the paper exit sensor flag
position OK? No Reposition the paper
exit sensor flag.
The paper take-up sensor
connector may be
disconnected. 6Is the paper take-up sensor
connector disconnected? Yes Connect it.
The paper exit sensor
connector may be
disconnected. 7Is the paper exit sensor
connector disconnected? Yes Connect it.
The paper exit sensor may be
dead. 8Replace it.
The paper take-up sensor may
be dead. 9Replace it.
Troubleshooting EPL-5500 Service Manual
5-8 Rev. B