Table 5-28. Print Quality Anomalies (Continued)
Symptom Possible Cause Part Name Check Item Remedy
Toner smudges on
the back side of the
sheet.
Improper charging PWB-F Replace the PWB-F
board.
Poor development PWB-F Replac e the PWB-F
board.
Improper fusing Fusing unit Replace the fusing unit.
Offset print Improper fusing Fusing unit Replace the fusing unit.
White spots Poor image
transfer Image transfer
unit Replace the image
transfer unit.
PWB-F Replace the PWB-F
board.
EPL-5500 Service Manual Troubleshooting
Rev. B 5-19