3.2.3.3 Upper Unit Removal
1. Open the upper unit.
2. Remove the right cover and left cover. (Refer to Section 3.2.1.1.)
3. Disconnect connectors CN202, CN208, and CN211 from the C169 MAIN-B.
4. Remove harness covers A and B, and pull out the CN1 of the PWB-E board.
5. Remove the image transfer unit. (Refer to Section 3.2.3.2.)
6. Slide and remove the unit as in the illustration.
A
B
Figure 3-9. Removing the Harness Cover
Figure 3-10. Removing the Uppe r Unit
EPL-5500 Service Manual Disassembly and Assembly
Rev. B 3-9