![](/images/backgrounds/156113/bg5b.png)
3.2.3.7 Fusing Unit Disassembly
This section describes how to remove the paper exit sensor, heater lamp, lower fusing roll er, and
upper fusing roller.
Heater Lamp
CAUTION
Do not touch the glass surface of the lamp with your bare hands.
1. Remove the fusing guide plate. (Refer to Section 3.2.3.6.)
2. Pull the heater lamp out of the lamp holder from the front side.
ASSEMBLY POINTS
When reinstalling the lamp, position its voltage indication to the left side (non-gear end.).
Figure 3-21. Removing the Heater Lamp
EPL-5500 Service Manual Disassembly and Assembly
Rev. B 3-15