Table 5-28. Print Quality Anomalies (Continued)Symptom Possible Cause Part Name Check Item Remedy
Blank print Poor development Imaging
cartridge Check whether the
toner cartridge is
installed properly.
Reinstall the toner
cartridge.
PWB-F board — Replace the PWB-F
board.
Improper charging PWB-F board — Replace the PWB-F
board.
Poor image
transfer Image transfer
unit Check the surface of
the image transfer unit. Replace the image
transfer unit.
PWB-F board — Replace the PWB-F
board.
Improper print
density setting — — Adjust the print density
in SelecType.
Defective optical
unit Optical unit — Replace the optical unit.
Black print Improper charging Photoconduc-
tor unit — Replace the
photoconductor unit.
PWB-F board — Replace the PWB-F
board.
Poor development Toner cartridge — Replace the toner
cartridge.
PWB-F board Replace the PWB-F
board.
Improper print
density setting — — Adjust the print density
in SelecType
Defective optical
unit Optical unit — Replace the optical unit.
White/black lines and
bands. Improper charging Photoconduc-
tor unit — Replace the imaging
cartridge.
Poor development PWB-F board — Replace the PWB-F
board.
Toner cartridge — Replace the toner
cartridge.
Dirt on the fusing
roller Fusing roller — Clean the fusing roller.
Troubleshooting EPL-5500 Service Manual