Troubleshooting

[ T E R M I N A L A S S I G N M E N T ]

Ho

 

#8 0

 

#I7

0

 

#6 0

 

#I5

0.

 

#4

0

 

#3 0

 

#2

0

 

#’

0

 

[ W I R E A S S I G N M E N T ]

1

Note: The commons correspond to the following printhead dot wires:

Note:

The printhead is upside down in this illustration.

J

COM. 2 = #2, #4, #6

COM. 8 = #7, #8, #9

COM. 14=#1,#3,#5

Figure 3-1. Printhead ResistanceTable 3-4. Printhead Test Points and Coil Resistance

 

 

 

 

Test Method

 

 

 

Common

Connector

(Set Meter to Ohms. Disconnect

 

 

Connector

Pin

Test Pin

Printhead and Check it with

 

 

Number

Numbers

Numbers

Printer Power Off.)

Meter Reading

 

 

 

 

 

 

 

Printhead

2

1,3,and5

Place one lead on pin 2 and the other on

16.5&-I *1.6S2

 

 

 

 

test pins 1,3, and 5 to check the

(at 77” F,

 

 

 

 

resistance of printhead dots #2, #4, and #6.

25” C)

 

 

8

4,6, and 13

Place one lead on pin 8 and the other on

 

 

 

 

 

test pins 4, 6, and 13 to check the

 

 

 

 

 

resistance of printhead dots #7, #8, and #9.

 

 

 

14

10,i 1, and 12

Place one lead on pin 14 and the other lead

 

 

 

 

 

on each of the test pins 10, 11, and 12 to

 

-

 

 

 

check the resistance of printhead dots

 

 

 

 

 

#l , #3, and #5.

 

 

 

 

 

 

 

 

Thermistor

-

7and9

Place one lead on each pin.

Approx. 9.3 K R

 

 

 

 

 

 

E p s o n FX-870/1170

3-3