B. SETUP WINDOW
On bottom cover of the Aura series thermal printer, there is screwed a metal plate for setup window. In this window, there is a 8 position DIP switch for printer setup. Please use proper tool to change the switch setting when necessary. The switch position counting starts from the nearest edge of printer. The ON direction points to the connector area of the printer. The OFF direction points to the power switch. The functions of each position may evolve with the revisions of the firmware. The information below applies to the latest version to the date of print of this manual.
This 8 position DIP switch works as following:
Switch | ON | OFF | |
position | |||
|
| ||
1 | RS232 baud rate definition or Parallel interface | ||
2 | definition (ref. separate table below) | ||
3 | Even parity | None parity | |
4 | XON handshaking | Hardware handshaking | |
5 | Busy on “buffer full” | Busy on “off line” | |
6 | Immediate cut | Protective cut | |
7 | CR code effective | CR code ineffective | |
8 | Factory internal setting | Application standard mode |
Effect of positions 1 & 2 on baud rate is defined as in table below with parity check set according to position 3, number of data bits always set to 8, and stop bit set to 1. When the parallel interface is used, please set both positions to ON.
SW Pos. 1 | ON | OFF | ON | OFF |
SW Pos. 2 | ON | ON | OFF | OFF |
Baud rate | 38400 bps / | 4800 bps | 9600 bps | 19200 bps |
or Interface | (Parallel) |
|
|
|
Switch position 3 defines the parity check regulation in serial interface. In Aura, it is selectable between even and none.
5 - 2