Epson T70 specifications Code, Signal Printer status DIP switch OFF, Xon

Models: T70

1 86
Download 86 pages 58.54 Kb
Page 67
Image 67

Appendix

XON/XOFF

When XON/XOFF control is selected, the printer transmits the XON or XOFF signals as follows. The transmission timing of XON/XOFF differs, depending on the setting of DIP switch 2-1.

Signal

 

Printer status

DIP switch 2-1

 

 

 

 

1 (ON)

0 (OFF)

 

 

 

 

 

 

 

XON

1) When the printer goes online after turning on the power (or

Transmit

Transmit

 

reset using the interface)

 

 

 

 

 

 

 

 

2)

When the receive buffer is released from the buffer full state

Transmit

Transmit

 

 

 

 

 

 

3)

When the printer switches from offline to online

Transmit

 

 

 

 

 

 

4)

When the printer recovers from an error using some ESC/POS

Transmit

 

commands

 

 

 

 

 

 

XOFF

5) When the receive buffer becomes full

Transmit

Transmit

 

 

 

 

 

 

6)

When the printer switches from online to offline

Transmit

 

 

 

 

 

Code

The hexadecimal numbers corresponding to the XON/XOFF codes are shown below.

XON code: 11H

XOFF code: 13H

When the printer goes from offline to online and the receive buffer is full, XON is not transmitted.

CAUTION When the printer goes from online to offline and the receive buffer is full, XOFF is not transmitted.

When DIP switch 1-3 is off, XON is not transmitted as long as the printer is offline, even if a receive buffer full state has been cleared.

67

Page 67
Image 67
Epson T70 specifications Code, Signal Printer status DIP switch OFF, Xon