Reliability

Life:

Mechanism:

15,000,000 lines

 

Thermal head:

100 million pulses,

 

 

100 km

 

Auto cutter:

1,500,000 cuts

 

(End of Life is defined to have reached the

 

end of its life when it reaches the

 

beginning of the Wearout Period.)

MTBF:

360,000 hours

 

 

(Failure is defined as Random Failure

 

occurring at the time of the Random

 

Failure Period.)

 

MCBF:

52,000,000 lines

 

 

(This is an average failure interval based

 

on failures relating to wearout and

 

random failures up to the life of 15 million

 

lines.)

 

Environmental Conditions

Temperature:

Operating:

5° to 45° C (41° to 113° F)

 

Storage:

–10° to 50° C (14° to

 

 

122° F), except for paper

Humidity:

Operating:

10 to 90% RH

 

Storage:

10 to 90% RH, except for

 

 

paper

Reference Information 4-5