Setting Operating Parameters

Complete this step prior to programming the door run time. This will dictate how your door will react during programming and normal op- eration.

It is not necessary to reset these if power is removed or if reset is tripped, they will stay set.

Important Dip Switch Setting

Verify the 4 dipswitches to the left of the display LED are as follows:

1. DOWN

2. DOWN

3. UP

4. UP

Entering programming mode

1.Make the necessary power connections and check the LED lights to be sure the appropriate lights are lit.

2. The display should show

3.Press and hold down P2 until the display shows parameter A with the corresponding number that is currently default or previously pro- grammed.

4.Press P1 to change the number variable of the parameter, USE THE

CHART ON THE NEXT PAGE AS A GUIDE.

5.To move to the next parameter, Press P2.

6.When 60 seconds have elapsed without any button being pressed the control unit automati- cally exits the programming mode. To exit manually, Press P2 to scroll through all the pa- rameters until the display shows

5.1