MENU
6.7 MOTION SETTING MENU
MOTION SETTING MENU
CH | OP | SEN | DURATION | |
1 | ON | HIGH | 05 | SECS |
2 | ON | HIGH | 05 | SECS |
3 | ON | HIGH | 05 | SECS |
4 | ON | HIGH | 05 | SECS |
(5 | ON | HIGH | 05 SECS) | |
(6. | ON | HIGH | 05 SECS) |
Press 1~6 TO MANUAL EDIT
Columns in brackets () only valid for
In the MOTION RECORD SETTING MENU, we define
(1)CH (Channel) : Video input channel
(2)OP (Operation) : Default: OFF
ON: The device will respond recording when motion occurs.
OFF: The device will not respond recording when motion occurs.
(3)SEN (Sensitivity) : HIGH, MIDDLE or LOW adjustable. Default: MIDDLE.
(4)DURATION: Duration time for motion record and Alarm Out relay.
0~99 seconds adjustable. Default: 05 seconds.
Note: Hit the numeric keys 1~4/6 to select a camera for setting the detection
areas.The selected camera appears with a 16 x 12 grid (detection zones). See
next page for details.
Turn the JOG dial clockwise or
Press ENTER key to confirm the option and move to next column.
ENTER
Press CALL key to confirm the option and move to previous column.
CALL
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU
17