EverFocus EDSR-600, EDSR-400 Alarm Record Setting Menu, In ALARM RECORDING MENU, we define

Models: EDSR-600

1 57
Download 57 pages 1.41 Kb
Page 21
Image 21
6.6 ALARM RECORD SETTING MENU

MENU

6.6 ALARM RECORD SETTING MENU

ALARM SETTING MENU

CH OP TYPE DURATION

1

ON

N.O

05 SECS

2

ON

N.O

05 SECS

3

ON

N.O

05 SECS

4

ON

N.O

05 SECS

(5

ON

N.O

05 SECS)

(6.

ON

N.O

05 SECS)

RST ON

N.O

 

Columns in brackets () only valid for EDSR-600

In ALARM RECORDING MENU, we define

(1)CH (Alarm input) : Select alarm input or RST for alarm reset input.

(2)OP (OPERATION) : ON : Records when alarm occurs.

OFF : No reaction when alarm occurs.

(3)TYPE : Select alarm type:

N.C. : Normally Closed with time out function counting from alarm start (set in DURATION)

N.C. + TRANS : Normal Closed, alarm duration as long as contacts is active + timeout (set in DURATION)

N.O. : Normal Open with time out function counting from alarm start (set in DURATION)

N.O. + TRANS: Normal Open, alarm duration as long as contact is active + timeout (set in DURATION)

(4)DURATION : Timeout duration time for each event. 0~99 seconds adjustable.

Turn the JOG dial clockwise or counter-clockwise to select the options.

Press ENTER key to confirm the option and move to next column.

ENTER

Press CALL key to confirm the option and move to previous column.

CALL

Press MENU key to return to Main Menu, press again to leave Set up Menu.

MENU

16

Page 21
Image 21
EverFocus EDSR-600, EDSR-400 instruction manual Alarm Record Setting Menu, In ALARM RECORDING MENU, we define