MENU

6.11 CONTROL SETTING MENU

CONTROL SETTING MENU

RS232

 

BAUD RATE

: 9600 BPS

STOP BIT

: 1

PARITY

: NONE

DATA BIT

: 8

RS485

: 9600 BPS

BAUD RATE

STOP BIT

: 1

PARITY

: NONE

DATA BIT

: 8

RS232/RS485 ID

: 1

In the CONTROL SETTING MENU, we define

(1)RS232 BAUD RATE: There are 6 different speeds that can be used to transmit instruction or information through the RS232 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 38400 baud. The default setting from the factory is 9600 baud.

(2)RS232 STOP BIT: Select stop bit: 1 or 2

(3)RS232 PARITY: Select parity mode: NONE/ODD/EVEN

(4)RS232 DATA BIT: Select data bit : 8 or 7

(5)RS485 BAUD RATE: There are 6 different speeds that can be used to transmit instruction or information through the RS485 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 38400 baud.

(6)RS485 STOP BIT: Select stop bit: 1 or 2

(7)RS485 PARITY:Select parity lever: NONE/ODE/EVEN

(8)RS485 DATA BIT: Select data bit : 8 or 7

(9)RS232/RS485 ID: RS232/RS485 address.The address range for the DVR: 1~200.

NOTE: Settings for remote keyboards KS -KBK and KS-KBJ:

RS-485 Baud rate: 9600, 1 Stop bit, Parity NONE, ID (device number) range: 1~32.

Turn the JOG dial clockwise or counter-clockwise to select the options.

Press ENTER key to confirm the option and move to next column.

ENTER

Press MENU key to return to Main Menu, press again to leave Set up Menu.

MENU

24

Page 29
Image 29
EverFocus EDSR-1600, EDSR-900 instruction manual Control Setting Menu, Control Setting MENU, we define