MENU

6.7 ALARM RECORD SETTING MENU

ALARM SETTING MENU

CH

OP

TYPE

DURATION

1

ON

N.O

05 SECS

2

ON

N.O

05 SECS

3

ON

N.O

05 SECS

4

ON

N.O

05 SECS

5

ON

N.O

05 SECS

6

ON

N.O

05 SECS

7

ON

N.O

05 SECS

8

ON

N.O

05 SECS

9

ON

N.O

05 SECS

10

ON

N.O

05 SECS

12

ON

N.O

05 SECS

13

ON

N.O

05 SECS

14

ON

N.O

05 SECS

15

ON

N.O

05 SECS

16

ON

N.O

05 SECS

RST

 

N.O

 

10 to 16 only valid for EDSR-1600

In ALARM RECORDING MENU, we define

(1)CH (Alarm input) : Select alarm input or RST for alarm reset input.

(2)OP (OPERATION) : ON : Records when alarm occurs.

OFF : No reaction when alarm occurs.

(3)TYPE : Select alarm type:

N.C. : Normally Closed with time out function counting from alarm start (set in DURATION)

N.C. + TRANS : Normal Closed, alarm duration as long as contacts is active + timeout (set in DURATION)

N.O. : Normal Open with time out function counting from alarm start (set in DURATION)

N.O. + TRANS: Normal Open, alarm duration as long as contact is active + timeout (set in DURATION)

(4)DURATION : Timeout duration time for each event. 0~99 seconds adjustable.

Turn the JOG dial clockwise or counter-clockwise to select the options.

Press ENTER key to confirm the option and move to next column.

ENTER

Press MENU key to return to Main Menu, press again to leave Set up Menu.

MENU

17

Page 22
Image 22
EverFocus EDSR-900, EDSR-1600 instruction manual Alarm Record Setting Menu, Alarm Recording MENU, we define