2.3.1. Address Setting
The address code of the EPTZ3000/EPTZ3000I should be set to correspond properly with a control device to control multiple dome cameras. The address codes are made up by the dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the
binary coded of the address, and there are 256 addresses can be selected (0 ~ 255, 28
=256). It also means that there are up to 256 dome cameras that can cascade on the
following chart.
Note: The factory default address is 1.
Notice: Please make sure the power is off before setting, and restart the EPTZ3000/EPTZ3000I to enable a new value after changing.
CPU
1 | ON | ID1 |
| ||
2 |
| ID2 |
3 |
| ID3 |
4 |
| ID4 |
5 |
| ID5 |
6 |
| ID6 |
7 |
| ID7 |
8 |
| ID8 |
|
|
|
SW1
SW2
1 |
|
|
| ON |
2 |
|
|
| |
|
|
| ||
|
|
|
| |
3 |
|
|
|
|
4 |
|
|
|
|
5 |
|
|
|
|
6 |
|
|
|
|
7 |
|
|
|
|
|
|
|
| |
8 |
|
|
|
|
|
|
|
|
|
BAUD Protocol