Example 3: Routed Network Configuration
NOTE: It is immaterial, in this example, which codec is the encoder and which is the
decoder. These functions are not identified in figure 8.
Figure 8 shows an example of a routed network configuration. Codec 1 is configured as the
controller, via LAN port 2.
The two codecs are connected across a wide area network (WAN) via an external router.
Network 1, connected to LAN port 1 (RJ-45 port), the “green” network — This
network is separated from the streaming network. This is the primary network for
system control and monitoring.
Network 2, connected to LAN port 2 (the fiber optic port), the “red” network
The encoder streams video on this network and it can also used for system control and
monitoring if desired.
NOTE: Selection of this network for streaming is via the built-in HTML network
interface. This selection is defined in the management interface, described
later (see “Configure Encoders or Decoders“).
The gateway IP addresses (the addresses on both sides of the router on the red network)
is set on LAN port 2 (configuration option 14) for both codecs.
This architecture provides isolation between the video transport and simple network
management protocol (SNMP) traffic.
NOTE: The SNMP protocol includes a system of SNMP trap messages. SNMP trap
messages can be initiated by a network element and sent to the network
management system.
Network 1
Network 2
N
etwor
k
2
Ne
tw
o
r
k
1
192.168.0.250 192.168.1.250
Local Network
Management Server
172.28.0.3
Browser 1
172.28.0.4
Browser 2
192.168.0.3
Network
Switch
Network
Switch Network
Switch
Network
Switch
Network
Switch
Network
Router
Network
Router
B
rowser
2
192
.
168
.
0
.
3
N
etwor
k
Swi
tch
VN-MATRIX 325 SERIES
SERIAL DIGITAL VIDEO OVER IP
LAN-1
LAN-2
STATUS
ALARM
TEST
Codec 1 LAN Port 2:192.168.0.1
Controller
LAN Port 1:172.28.0.1
N
etwor
k
Swi
tch
VN-MATRIX 325 SERIES
SERIAL DIGITAL VIDEO OVER IP
LAN-1
LAN-2
STATUS
ALARM
TEST
Codec 2
LAN Port 2:192.168.1.1
LAN Port 1:172.29.1.1
Browser
172.29.1.4
Figure 8. Routed Network Configuration
VN-Matrix 325 Serial Digital Over IP CODEC • Installation and Setup 15