Replacing Cables or an AAP

ATTENTION: Potential damage to property. Do not overtighten the Phillips head screws on the screw clamps. Overtightening can bend the horizontal flange of the screw clamp.

10.Snugly tighten the Phillips head screws on the screw clamps to secure the enclosure to the surface.

11.Tighten the locking thumbscrews on the screw clamps to lock the clamp in position.

Replacing Cables or an AAP

Before you change the cables or replace one or more AAPs inside the cubby, you must remove the AAP shelf assembly from the Cable Cubby. Use the following guidelines as applicable:

1.If the Phillips head screws on the front and rear of the cubby are blocked by the table, remove the cubby from the table. See “Removing and Replacing the Cable Cubby” steps 1 through 4, on page 12.

2.Remove the AAP shelf assembly(ies) by removing the four Phillips head screws on the front and rear of the Cable Cubby and gently pushing the assembly out through the bottom of the cubby.

3.Change the cables and AAPs the same way you installed them. See “Installing the Cables and AAPs” on page 7.

4.If you removed the cubby from the table, reinstall the enclosure. See “Removing and Replacing the Cable Cubby,” steps 7 through 10, on page 13.

Adding an Additional Power Module (CC 600 and CC 800)

Each additional USA/domestic power module occupies two AAP spaces, and each international power module (optional) occupies three AAP spaces. Additional power modules reduce the amount of AAP space available in the cubby for cable pass-through (split) or passive AAPs. Use the following guidelines as applicable:

NOTE: The universal AC outlet is fully compatible with various plug types. See the Universal AC Outlet Compatibility Guide on the Extron website, www.extron.com, for compatibility details on all plug types.

1.Replacement two-space, three-space, and four-space shelf brackets and cable pass-through (split) AAPs are available from Extron, and may be required to maximize the remaining available space if you add a power module.

Cable Cubby 300 models — Adding a second power module is not recommended. With a second power module, there is either room left for only a single one-space AAP or no AAP space left at all (depending on the model).

Cable Cubby 600 and 800 (AC module optional) — In general, you probably do not need replacement shelf brackets when you add an international module to a Cable Cubby with no pre-installed power module. The power module replaces a three-space shelf that is standard in all Cable Cubby models with no pre-installed power module.

Figure 12 on the next page shows the typical configurations of one and two international power modules installed in a Cable Cubby 600 with no pre-installed power module.

Cable Cubby 300/600/800 • Maintenance and Modifications 14