Figure 13. Firmware Loader Screen with a DP DA2 Added
12.If you want to remove a device from the Devices section, do the following:
a.Click on the names of the devices to be deleted, to highlight them.
b.Select Remove Selected Device(s) from the Edit menu.
c.On the Remove Device(s) window, select or deselect any devices on the list as desired, then click Remove.
To remove all devices, select Remove All Devices from the Edit menu.
13.Click Begin. The following indicators show the progress of the update:
•The Transfer Time section shows the amounts of remaining and elapsed time for the update.
•The Total Progress section displays a progress bar with Uploading... above it.
•In the Devices section, the Progress column displays an incrementing percentage and another progress bar. The Status column displays Uploading.
14.The upload is complete when the Remaining Time field shows 00.00.00, the Progress column shows 100%, and Completed is displayed above the progress bar and in the Status column. Close the Firmware Loader window.
Resetting Firmware to the Factory Default Version
Occasionally the newly installed firmware may conflict with the system. If that occurs, it will be necessary to restore the original
Use a small screwdriver to press the reset button for 10 seconds while powering on the DP DA2. The front panel power LED blinks amber three times, then lights solid amber, and finally blinks amber three more times while the reset occurs. When the reset is complete, the power LED lights solid green.
Reset Button
Figure 14. Firmware Reset Button on the Base of the DP DA2
DP DA2 • Updating Firmware | 21 |