Installation Overview

All three distribution amplifiers can be mounted on tabletops, under furniture, and in racks by following these steps:

1.Ensure that the input sources, the distribution amplifier and the output display(s) are all turned off and all power sources and signal cables are disconnected.

2.Mount the unit as described in "Mounting the Distribution Amplifier", below.

3.Connect the cables (see page 2-9).

4.Plug in the power supply, turn on the display devices and, finally, turn on the input devices (see page 2-11).

Mounting the Distribution Amplifier

All three of these units can be mounted in racks, under furniture or on tabletops.

Tabletop placement

Attach the four provided rubber feet to the bottom of the unit and place it in any convenient location.

Rack mounting

UL guidelines for rack mounting

The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of these products in a rack:

1.Elevated operating ambient temperature — If the unit is installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the equipment in an environment compatible with the maximum ambient temperature (Tma: +122 °F, +50 ° C) specified by Extron.

2.Reduced air flow — Install the equipment in the rack so that the equipment gets adequate air flow for safe operation.

3.Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition.

4.Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Give appropriate consideration to the equipment nameplate ratings when addressing this concern.

2-2 DVI DA Plus Series • Installation and Operation