Extron electronic DVI DL 201 Rx, DVI DL 201 Tx user manual Power on the local monitor, if required

Models: DVI DL 201 Tx DVI DL 201 Rx

1 48
Download 48 pages 14.35 Kb
Page 37
Image 37

Using pass-through mode with DDC routed to the remote display

NThis is the factory default setting.

N Although DDC can be routed to the remote display, there may be instances when the signals become corrupted or weak. In those cases, the source device may be unable to

 

boot up correctly.

 

 

MINDEREDID

EDIDDEFAULT

 

DDCREMOTE

 

 

 

 

 

 

 

 

 

 

 

1.

Set the EDID Minder switch to the off (down)

 

 

 

 

 

 

 

 

 

 

 

position and the Remote DDC switch to the

 

 

 

 

 

 

 

 

 

 

 

on (up) position (see the figure at right). The

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position of the Default EDID switch is not

ON

 

 

 

 

 

 

relevant.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Connect the source device to the transmitter

OFF

 

1

 

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

input.

3. Connect the display device to the receiver output and, if required, the local monitor to the transmitter output.

4. Connect the transmitter to the receiver with the three twisted pair cables.

Transmitter port 1 connects to receiver port 1.

Transmitter port 2 connects to receiver port 2.

Transmitter port 3 connects to receiver port 3. 5. Power on the remote display.

6. Boot up the source device. The source boots with the resolution and refresh rate of the remote display.

NBecause the remote display is the source of EDID, it must be powered on before the source device is booted.

7. Power on the local monitor, if required.

NIf used, the local monitor must be capable of handling a resolution equal to or greater than that of the remote display.

DVI DL 201 Tx/Rx • Configuration and Operation

3-5

Page 37
Image 37
Extron electronic DVI DL 201 Rx, DVI DL 201 Tx user manual Power on the local monitor, if required