Continue the procedure for installing the SGS 408.

6

Attach power cords and plug the SGS 408 seamless

 

switcher, ECP 1000 event control panel, input devices, and

 

output devices into a grounded AC source.

7

Select an input from the front panel buttons on the

 

SGS 408 switcher or RCP 1000 remote control unit.

8

The image should now appear. If not, ensure that all

100-240V 50/60 Hz 0.5A

TO SGS

3

2

1

PROGRAM

devices are plugged in and receiving power. Check the

cabling and make adjustments as needed. Select a

different input to check for a display.

1

2

3

4

Figure 2-1 — ECP 1000 rear panel

1

AC power connector — One standard AC power connector

 

attaches the event control panel to any power source from

 

100VAC to 240VAC, operating at 50 or 60 Hz.

2

Cooling fan — One fan cools the ECP 1000 unit. The filter can

 

be removed and washed as needed. See page A-2 for

 

instructions.

3

RS-232/program connector — One 9-pin D female connector

 

allows you to communicate with Extron’s SGS 408 Control

 

Program.

4

RS-232/SGS 408 connectors — Three 9-pin D female connectors

Projectors

SGS 408

SGS 408

 

SGS 408

allow you to attach an ECP 1000 event control panel to up to

three SGS 408 seamless switchers. The connectors correspond to

the screen selection buttons on the ECP 1000’s top panel.

Installation

To install and set up the ECP 1000, follow these steps:

1

Mount the SGS 408 switcher(s) as described in the SGS 408

 

User’s Manual (Extron part number 68-520-01).

2

Set the ECP 1000 on a flat surface.

 

For each SGS 408 to which the ECP 1000 will be connected,

3

Program

Monitor

Preview

Monitor

Program

Monitor

Preview

Monitor

ECP 1000

Up to 50'

0 1 ECP

100 RCP

0 01 RCP

RCP 1000

010 RPC

Control Room

Program

Monitor

Preview

Monitor

attach an ECP comm cable (provided with the SGS 408)

between an SGS connector on the ECP 1000 and the RS-232

connector on the SGS 408. Figure 2-2 shows a typical

application.

4 If desired, attach a host computer or other control device

to the RS-232/program connector.

Figure 2-2 — SGS 408 and ECP 1000 application