Installation, cont’d

Cabling and Installing the AAPs

The space behind the AAP panel is limited. The online Connectivity Configurator, available at www.extron.com, offers guidance as to the fit of AAPs into this space.

Extron’s various single space and double space AAP devices, including the various RGB 580xi AAPs, can be mounted to the HSA 822. See appendix A, “Reference Information”, for RGB 580xi AAP part numbers.

The screws for installing an AAP are built into its AAP panel, so no additional screws are needed.

Ensure that AC power is disconnected before

servicing the HSA unit.

1. Remove the top and bottom screws on the right and left

sides of the AAP panel (figure 2-4). Retain the screws. Lift

the panel away from the enclosure as far as the connected

cables allow and then allow the panel to dangle,

supported by its connected cables.

Remove two screws ea. side.

Remove panel.

HSA822

Replacement Face Plate

Screws (4) Under Enclosure

Figure 2-4 — Removing the AAP panel from an HSA 822

 

 

The center screws on each side of the AAP panel do not

 

 

fasten the AAP panel in place. They secure the

 

 

AC power outlet.

 

 

Ensure that the edges of the AAP panels do not scratch

 

 

 

 

the finished surface of the top panel flange when

 

 

removing the panels.

2.

Cable the rear of the AAPs before fastening the AAPs to

 

the AAP panel. Route the cables through the hole in the

 

underside of the surface mount enclosure and connect

 

them to the rear of the AAPs. If applicable, refer to the

 

cabling information in the documentation for the AAP.

3.

Insert each of the AAP’s screws through the holes in the

AAP Panel

INP

 

 

 

 

 

S

UT

 

 

 

 

 

ELE

CO

 

A

 

 

 

CT

MP

UD

IO

 

 

 

UTER

 

#4-40 Nut w/ Captive Washer

Cable

HSA

822

 

RGB 580xi SI AAP

AAP opening of the HSA AAP panel. Secure each AAP to

the panel with the provided captive washers and #4-40

nuts (figure 2-5).

Figure 2-5 — Mounting an AAP device on the AAP panel

4. Replace the AAP panel in the surface mount enclosure and secure it in place with the screws removed in step 1. If you lose an AAP panel screw, four spare screws are stored in the underside of the enclosure.