Maintenance and Modifications
The HSA 822 surface mount enclosures can be modified in the future to replace an AAP. The most probable corrective maintenance procedures required are leveling the top surface and replacing the gas lift. Most of the maintenance procedures require removing the surface mount enclosure from the table.
Replacing an AAP
Replace one or more AAPs as follows:
|
|
|
|
| Ensure that AC power is disconnected before |
|
|
|
|
| servicing the HSA unit. |
1. | On the underside of the clamshell and in the enclosure, cut | ||||
| the tie wraps that route the AAP cables out of the way. | ||||
2. | Remove the top and bottom screws on the right and left | ||||
| sides of the AAP panel (figure | ||||
| the panel away from the enclosure as far as the connected | ||||
| cables allow and then allow the panel to dangle, | ||||
| supported by its connected cables. | ||||
|
|
| The center screws on each side of the AAP panel do not | ||
|
|
| |||
|
|
| fasten the AAP panel in place. They secure the | ||
|
|
| AC power outlet. | ||
|
|
| Ensure that the edges of the AAP panels do not | ||
| CAUTION |
| |||
|
|
|
|
| scratch the finished surface of the top panel flange |
|
|
|
|
| or the furniture in which the HSA 822 is installed |
|
|
|
|
| when removing the panels. |
Remove two screws ea. side.
INPUT |
|
|
SELECT | COMPUTER | O |
| AUDI |
Remove panel.
HSA822
Figure 3-1 — Removing the AAP panel
3. | Disconnect any cables from the rear of the AAPs that are |
| being replaced. If a cable is no longer required in your |
| system, carefully pull the cable through and out the |
| bottom of the surface mount enclosure and the clamshell. |
4. | Remove the AAP(s) that you no longer want from the AAP |
| panel by unscrewing the nuts on the rear of the AAP panel |
| that secure the AAPs in place (figure |
|
|
|
| ||
|
|
|
|
| Washer |
AAP Panel |
|
|
|
|
|
|
|
|
|
| Cable |
S UT |
|
|
| HSA |
|
INP |
|
|
|
| 822 |
ELE |
| A |
|
| |
CT CO | MP | UD | IO |
| |
|
|
| |||
| UTER |
|
|
RGB 580xi SI AAP
Figure 3-2 — Mounting an AAP device
5.Cable the rear of the AAPs to be installed before attaching the AAPs to the enclosure. Route the cables through the hole in the underside of the surface mount enclosure and connect them to the rear of the AAPs. If applicable, refer to the cabling information in the documentation for the AAP.
6. | Insert each AAP’s screws through the holes in the AAP |
| opening of the AAP panel. Secure each AAP to the panel |
| with the provided captive washers and |
7. | Replace the AAP panel in the surface mount enclosure and |
| secure them in place with the screws removed in step 2. If |
| you lose an AAP panel screw, four spare screws are stored |
| in the underside of the enclosure (see figure |
| page |
8. | To prevent wear and tear caused by cable movement, |
| secure the AAP cables underneath the table. See |
| page |
HSA 822 Hideaway® Enclosure • Maintenance and Modifications |