Installation, cont’d

Cabling the Enclosure

Bottom panel features

3

 

2

 

1

 

 

4

1

 

3

5

Figure 2-6 — HSA 822 enclosure underside connectors

1RJ-45 connectors — See Cabling the RJ-45 connectors below.

All RJ-45 connectors are teminated in accordance with the TIA/EIA 568 A standard.

2AC power connector — Connect this cord to the power source.

For US-domestic versions, this power cord is permanently connected to the HSA. Connect the power cord to a 125 VAC,

60 Hz, 10 A power source.

For international versions, this power cord is a removable IEC power cord. Connect the cord to a 220-250 V, 50/60 Hz, 10 A power source.

3Cable access holes

4Spare AAP panel screws

5Top panel height adjustment screw — See “Adjusting the height of the top surface” in chapter 3, “Maintenance and Modifications”.

Cabling the RJ-45 connectors

Plug one end of a CAT 5 or CAT 6 twisted pair (TP) cable into each of these RJ-45 female connectors. Connect the other end to

an appropriate telecommunications or data network or to an Extron TP product.

An RJ-11 (telephone) plug can be connected to the RJ-45 jack.

When cabling the AAP panels and the bottom panel, the bottom RJ-45 connectors match up with the AAP panel RJ-45 connectors as shown in figure 2-7. For example, match the AAP panel RJ-45 connector A1 with the underside RJ-45 connector A1, match A2 with A2, and so forth.

B1

A1

 

A2

B2

 

 

B1

 

B2

A1

A2

 

Figure 2-7 — HSA 822 RJ-45 connectors

If necessary have a qualified service person replace the connector icon on the AAP panel by prying the old icon off of the connector plug-in with a tweeker or small screwdriver (figure 2-8) and snapping a new icon in place.

Icon Labels

Figure 2-8 — Changing the connector icon

2-10 HSA 822 Hideaway® Enclosure • Installation

HSA 822 Hideaway® Enclosure • Installation 2-11

Page 12
Image 12