Maintenance and Modifications, cont’d
Adjusting the Top Surface
The top lifting panel of the HSA 822 can be adjusted to raise or lower its level flush with the flange. It can also be adjusted to ensure that the lifting panel is horizontal and not tipped.
Adjusting the height of the top surface
You may be able to adjust the height of the top lifting panel without removing the HSA 822 from the table. If you can reach the height adjustment lock screw slots (figure
Height Adjustment
Locking Screw Slots
Figure 3-7 — Height adjustment locking screw slots
Raise or lower the lifting panel flush with the flange as follows:
1. | If you cannot access the height adjustment locking screw |
| slots in the side of the HSA enclosure, remove the surface |
| mount enclosure from the table. See “Removing and |
| Replacing the Enclosure”, steps 1 through 9. Place the |
| enclosure on its side on a horizontal surface. To protect |
| the finish, place the enclosure on a soft cloth. |
2. | If necessary, close and latch the top panel. |
3. | Slightly loosen the two locking screws (figure |
Loosen locking screws.
Adjustment
Screw
Figure 3-8 — Height adjustment screw location
4. | Turn the height adjustment screw counter clockwise to |
| raise the lifting plate or clockwise to lower the plate |
| (figure |
5. | Tighten the two locking screws that you loosened in step 3. |
6. | If removed, reinstall the surface mount enclosure in the |
| table. See “Removing and Replacing the Enclosure”, steps |
| 12 through 18. |
HSA 822 Hideaway® Enclosure • Maintenance and Modifications |