Maintenance and Modifications, cont’d

Adjusting the Top Surface

The top lifting panel of the HSA 822 can be adjusted to raise or lower its level flush with the flange. It can also be adjusted to ensure that the lifting panel is horizontal and not tipped.

Adjusting the height of the top surface

You may be able to adjust the height of the top lifting panel without removing the HSA 822 from the table. If you can reach the height adjustment lock screw slots (figure 3-7) in the side of the enclosure with a long Phillips-head screwdriver, you should not need to remove the HSA from the table.

Height Adjustment

Locking Screw Slots

Figure 3-7 — Height adjustment locking screw slots

Raise or lower the lifting panel flush with the flange as follows:

1.

If you cannot access the height adjustment locking screw

 

slots in the side of the HSA enclosure, remove the surface

 

mount enclosure from the table. See “Removing and

 

Replacing the Enclosure”, steps 1 through 9. Place the

 

enclosure on its side on a horizontal surface. To protect

 

the finish, place the enclosure on a soft cloth.

2.

If necessary, close and latch the top panel.

3.

Slightly loosen the two locking screws (figure 3-8).

Loosen locking screws.

Adjustment

Screw

Figure 3-8 — Height adjustment screw location

4.

Turn the height adjustment screw counter clockwise to

 

raise the lifting plate or clockwise to lower the plate

 

(figure 3-8).

5.

Tighten the two locking screws that you loosened in step 3.

6.

If removed, reinstall the surface mount enclosure in the

 

table. See “Removing and Replacing the Enclosure”, steps

 

12 through 18.

3-12 HSA 822 Hideaway® Enclosure • Maintenance and Modifications

HSA 822 Hideaway® Enclosure • Maintenance and Modifications 3-13