Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response
IP Setup Commands
Set Unit name24 E
X1@ CN}W
X1@ CN|Ipn •
X1@]
Set Unit name to factory default24 E • CN}W %20 CN|Ipn •
X4(]
Read Unit name E CN}WCN| X1@]
Set time/date24 EX1# CT}W
X1# CT|Ipt •
X1#]
Read time/date E CT}WCT| X1#]
Set GMT offset24 E
X# CZ}W
X# CZ|Ipz
X#]
Read GMT offset E CZ}WCZ| X#]
Set daylight saving time E
X3$ CX}W
X3$ CZ|Ipx
X3$]
Read daylight saving time E CX}WCX| X3$]
Set DHCP on24 E 1DH}W1DH|Idh1]
Set DHCP off24 E 0DH}W0DH|Idh0]
View DHCP mode E DH}WDH| X%]
Set IP address24 E
X1$ CI}W
X1$ CI|Ipi •
X1$]
Read IP address E CI}WCI| X1$]
Read hardware address (MAC) E CH}WCH| X1*]
Set subnet mask E
X1(
CS}W
X1( CS|Ips •
X1(]
Read subnet mask E CS}WCS| X1(]
Set gateway IP address E
X1$ CG}W
X1$ CG|Ipg •
X1$]
Read gateway IP address24 E CG}WCG| X1$]
Set administrator password24 E
X3# CA}W
X3# CA|Ipa •
X3#]
Clear administrator password24 ECA}W %20 CA|Ipa
]
Read administrator password24 E CA}WCA| X3#]
Set user password24 E
X3# CU}W
X3# CU|Ipu •
X3#]
NOTE: X# = Greenwich Mean Time (GMT) offset value (-12.0 to +14.0)
X% = On/off status: 0 = off/disable; 1 = on/enable
X1@ = Name is a text string up to 24 characters drawn from the alphabet, digits, minus sign/hyphen. No blank or space characters are permitted.
X1# = Set local date and time format (MM/DD/Y-HH:MM:SS); Read local date and time format (day of week, date month year HH:MM:SS)
X1$ = IP address
X1* = Hardware (MAC) address
X1( = Subnet mask
X3# = Password: maximum length of 12 characters and no special characters
X3$ = Daylight saving time: 0 = off/ignore; 1 = on (use in northern hemisphere) (USA); 2 = on (Europe); 3 = on (Brazil)
X4( = Default Name: combination of model name and last 3 pairs of MAC address.
IPL T CR48 • Communication and Control 29