6.If passwords were set up for the connected system, you will be prompted to log in as Administrator or User. Otherwise, the system responds with a <cr/lf>.

7.Once you are connected, you can enter serial (ASCII) commands as desired.

8.When you are through entering commands to the IPL T CR48, type quit at the command prompt to quit Telnet.

Troubleshooting

For best results, make connections in the following order. Turn on:

1.Control devices (such as a PC or laptop)

2.IPL T CR48

3.Output devices (such as projector lifts, screen lifts, and lighting systems)

If the output A/V device cannot be remotely controlled, check the following:

Power Connections

1.Ensure that all devices are plugged in.

2.Ensure that each device is receiving power. The power LED on the front panel of the IPL T CR48 lights if the device is receiving power.

Data Connections

1.Check the cabling connections and make adjustments as needed. The LINK LEDs on the IPL T CR48 and the computer should be solid green if a network connection is detected. If these LEDs are not lit, either the cable is faulty or not plugged in, or the wrong

type of cable is being used (see Connecting the Hardware in the “Connection and Configuration” section).

2.Try to ping the unit by typing ping 192.168.254.254 at the Windows command prompt, or use the Web address provided to you by your system administrator. If you get no response:

a.Ensure that your unit is using the appropriate subnet mask (check with your system administrator).

b.Ensure that your PC does not have a software firewall program that might block the IP address of the unit.

3.If contact is established with the unit but the unit Web pages cannot be accessed by your Web browser, verify (in the Options or Preferences menu of the browser) that your Web browser is configured for direct network connection and not set up to use a proxy server.

If you are still experiencing problems, call the Extron S3 Sales & Technical Support Hotline.

Configuration

If, when configuring a unit, the MAC address on the rear panel is not visibly accessible and the IP address is not known, use the direct PC connection method (see the Connection and Configuration section).

NOTE: If the unit is not new (for example, out of the box), please see Resetting the

Controller in the “Installation and Operation” section for instructions on how to reset the IP back to factory default.

IPL T CR48 • Communication and Control

34

Page 40
Image 40
Extron electronic IPL T CR48 manual Troubleshooting, Power Connections, Data Connections, Configuration

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.