Symbol definitions are shown below. An ASCII to HEX conversion table is also provided in

figure 21.

ASCII to Hex Conversion Table

Space

Figure 21. ASCII-to-HEX Conversion Table

Symbol definitions

]

}

X!

X#

X%

X1!

X1@

X1#

X1$

X1%

X1*

X1(

X2@

=CR/LF (carriage return/line feed)

=Carriage return (no line feed)

=Space (hard) character

=Specific port number (01-99)

The port number will be represented as two ASCII characters (2 bytes)

=Greenwich Mean Time (GMT) offset value (-12.0 to +14.0)

=On/off status: 0 = off/disable; 1 = on/enable

=Unit version number

=Name is a text string up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and

minus sign/hyphen (-). No blank or space characters are permitted as part of a name. No distinction is made between upper and lower case. The first character must be an alpha character. The last character must not be a minus sign/hyphen.

=Set local date and time format (MM/DD/YY-HH:MM:SS) for example, 06/18/10-10:54:00; Read local date and time format (day of week, date month year HH:MM:SS) for example, Fri, 18 Jun 2010 18:19:33

=IP address (xxx.xxx.xxx.xxx); leading zeros in each of four fields are optional in setting values and are suppressed in returned values

=Mail Domain name (for example, extron.com, icia.org)

=Hardware (MAC) address (xx-x-xx-xx-xx-xx)

=Subnet mask (xxx.xxx.xxx.xxx); leading zeros in each of four fields are optional in setting values and are suppressed in returned values

=Verbose/response mode status: 0 = clear, default for Telnet connections; 1 = verbose mode is on;

2 = send tagged responses for queries; 3 = verbose mode is on and tagged responses are sent for queries

NOTE: If tagged responses are enabled, all read commands return the constant string + the

data or value, the same as in responses for setting a value. For example, for E CN }, the response is Ipn• X1@ ] rather than just the data (X1@ ]).

X2#

X3#

=Priority status for receive timeout: 0 = priority set to Send Data String command parameters;

1= priority set to configure received timeout command parameters.

=Password: maximum length of 12 characters and no special characters.

NOTE: User password cannot be assigned if no administrator password exists and returns E14. If the administrator password is cleared, then the user password is also removed.

X3$

X3%

X3^

X3&

=Daylight saving time: 0 = off/ignore; 1 = on (use in northern hemisphere) (USA) ; 2 = on (Europe); 3 = on (Brazil)

=Event number: range = 0 - 99 (max.)

=Event buffer: 0 = receive; 1 = user (absolute); 2 = user (relative); 3 = NVRAM

=Event buffer offset: range = 0 - MaxBufferSize

IPL T CR48 • Communication and Control

24

Page 30
Image 30
Extron electronic IPL T CR48 manual Symbol definitions, ASCII-to-HEX Conversion Table

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.