Command/response table for SIS commands (continued)
Command ASCII (Telnet) URL Encoded (Web) Response
Reset Web port map24 E 80MH}W 80MH|Pmh00080]
Disable Web port map24 E 0MH}W 0MH|Pmh00000]
Read Web port map24 E MH}WMH|port#]
Web Browser Specific
Read response from last URL cmd E UB}W UB|response from command]
E-mail
Configure e-mail events24 E
X4%,
X4^,
X4& CR}W
X4% %2C
X4^
%2CX4&
CR|Ipr
X4%,
X4^,
X4&]
Read e-mail events E
X4% CR}W
X4%
CR| X4^,
X4&]
Send e-mail (event)24 E
X4% SM}W
X4%
SM|Eml
X4%]
Set mail server IP, domain name 24 EX1$,
X1%
CM}W
X1$
%2C
X1%
CM|Ipm
X1$,
X1%]
Read mail server IP, domain name E CM}WCM| X1$,
X1%]
Event Control
Read event buffer memory27 EX3%,
X3^,
X3&,
X3*
E}WX3%
%2CX3^
%2CX3&
%2CX3*
E| X5$]
Write event memory24 27 EX3%,
X3^,
X3&,
X3(,
X3*
E}W
X3%
%2CX3^
%2CX3&
%2CX3(
%2CX3*
E|Evt
X3%,
X3^,
X3&,
X3(]
Read string from event memory 27 EX3%,
X3^,
X3&,
X4$
FE}W
X3%
%2CX3^
%2CX3&
%2CX4$
FE|string]
Write string to event memory24 27 E
string*
X3%,
X3^,
X3&
FE}W string
%2AX3%
%2CX3^
%2CX3&
FE|EvtX3%,
X3^,
X3&
string]
Start events24 27 E 1AE}W1AE|Ego]
Stop events24 27 E 0AE}W0AE|Est]
Read number of events running E AE}WAE|Enm#####]
NOTE: X1$ = IP address
X1% = Mail domain name
X3% = Event number: range = 0-99 (max)
X3^ = Event buffer: 0 = receive; 1 = user (absolute); 2 = user (relative); 3 = NVRAM
X3& = Event buffer offset: range = 0-MaxBufferSize
X3* = Event data size: bit; Byte (8-bit); Short (16-bit); Long (32-bit) (only first letter is required)
X3( = Event data to write
X4$ = Number of bytes to read
X4% = E-mail recipient number: range = 1 - 64 max
X4^ = E-mail recipient address: max number of characters for full e-mail address is 31 characters
X4& = Name of e-mail file to be sent
X5$ = ASCII digits representing numeric value of data element read from event buffer
IPL T CR48 • Communication and Control 31