Remote Control, cont’d

Connecting an MMX 32 AAP or MMX 32 MAAP control panel

Each Extron MMX 32 AAP and MMX 32 MAAP contact closure remote control panel can control one output on the switcher. To connect a panel to the switcher, wire the captive screw connectors on the rear of the panel as follows.

43

2 5

1

Figure 3-8 — MMX 32 AAP rear panel

34

2

5

1

Figure 3-9 — MMX 32 MAAP rear panel

Input Selection connector

1Input 1 pole — Connect this pole of the captive screw connector to pin 1 (if the panel will control output 1) or pin 7 (if the panel will control output 2) of the MMX 32 VGA A’s Remote connector.

2Input 2 pole — Connect this pole of the captive screw connector to pin 4 (output 1) or pin 8 (output 2) of the MMX 32 VGA A’s Remote connector.

3Input 3 pole — Connect this pole of the captive screw connector to pin 6 (output 1) or pin 9 (output 2) of the MMX 32 VGA A’s Remote connector.

Tally Power connector

45 VDC pole — Connect this pole of the captive screw connector to the 5 VDC pole of the Tally Pwr connector on the

MMX 32 VGA A.

5GND pole — Connect this pole of the captive screw connector to the ground pole of the Tally Pwr connector on the

MMX 32 VGA A.

Control

Document

Camera

Extron

MMX 32 VGA A

 

 

Matrix Switcher

Audio System

 

Podium

LCD Monitor

 

Extron

Computer

 

with Audio

Projector

 

AAP 102 with

 

 

 

 

 

MMX AAP

 

Laptop

 

Figure 3-10 — Typical MMX 32 VGA A application using contact closure remote control

Only one MMX 32 AAP or MMX 32 MAAP control panel can be used to control each output.

Extron recommends shielded twisted pair cable, such as STP 22 dual plenum cable, part #22-162-03(or equivalent). Unshielded cable can allow crosstalk and interference between the MMX and the control panel.

3-14 MMX 32 VGA A • Remote Control