Installation and Operation

Mounting the MMX 32 VGA A

The MMX 32 VGA A can be set on a table, mounted on a rack shelf, or mounted under a desk, podium, or tabletop.

Tabletop use

Four self-adhesive rubber feet are included with the switcher. For tabletop use, attach one foot at each corner of the bottom of the unit, and place the unit in the desired location.

Rack mounting

For optional rack mounting, mount the switcher on any of the following rack shelves:

VersaTools® 19" 1U rack shelf kit (part #60-190-20) (figure 2-1)

VersaTools 19" basic 1U rack shelf (part #60-604-20)

6" deep 1U rack shelf kit (part #60-190-10)

6" deep basic 1U rack shelf (part #60-604-10)

Standard universal 1U rack shelf kit (part #60-190-01) (figure 2-2)

Basic universal 1U rack shelf (part #60-604-01)

Use 2 mounting holes on opposite corners.

1

OUTPUT2

 

 

1

3

1

OUTPUT2

 

 

2

3

MMX

32

VGA A

 

 

False Front panel uses 2 screws.

(2) 4-40 x 3/16" screws

Figure 2-2 — Mounting the MMX 32 VGA A on a 1U Universal rack shelf

UL requirements

The following Underwriters Laboratories (UL) requirements pertain to the installation of the MMX into a rack.

1.

Elevated operating ambient — If installed in a closed or

 

multi-unit rack assembly, the operating ambient

 

temperature of the rack environment may be greater than

 

room ambient. Therefore, consider installing the

 

equipment in an environment compatible with the

VersaTools Rack Shelf

False Front panel uses 2 screws.

1

OUTPUT2

 

 

1

3

Use 2 mounting holes on opposite corners.

1

OUTPUT2

 

 

2

3

MMX

32

VGA A

 

 

(2) 4-40 x 3/16" screws

 

maximum ambient temperature (Tma) specified by the

 

manufacturer.

2.

Reduced air flow — Installation of the equipment in a

 

rack should be such that the amount of air flow required

 

for safe operation of the equipment is not compromised.

3.

Mechanical loading — Mounting of the equipment in the

 

rack should be such that a hazardous condition is not

 

achieved due to uneven mechanical loading.

4.

Circuit overloading — Consideration should be given to

 

the connection of the equipment to the supply circuit and

 

the effect that overloading of the circuits might have on

 

overcurrent protection and supply wiring. Appropriate

 

consideration of equipment nameplate ratings should be

 

used when addressing this concern.

5.

Reliable earthing (grounding) — Reliable earthing of

Figure 2-1 — Mounting the MMX 32 VGA A on a VersaTools rack shelf

rack-mounted equipment should be maintained.

Particular attention should be given to supply connections

other than direct connections to the branch circuit (such as

the use of power strips).

2-2

MMX 32 VGA A • Installation and Operation

MMX 32 VGA A • Installation and Operation 2-3