Maximum Transmitter to Receiver Distance — Analog Signals at 60 Hz

Video Format

With Pre-Peak Off. With Pre-Peak On.

Feet (Meters)

Feet (Meters)

Max. Distance

Max. Distance

(High Quality).

(Variable Quality).

Feet (Meters)

Feet (Meters)

 

 

 

Composite,

 

 

 

 

 

 

S-video,

 

 

800 (245)

1000 (300)

 

 

Component Video

 

 

 

 

 

 

640 x 480

<300 (90)

>350 (105)

700 (215)

750 (230)

 

 

 

 

 

 

 

 

 

800 x 600

<300 (90)

>350 (105)

550 (170)

650 (200)

 

 

 

 

 

 

 

 

 

1024 x 768*

<300 (90)

>350 (105)

500 (150)

600 (185)

 

 

 

 

 

 

 

 

 

1280 x 960

<300 (90)

>350 (105)

400 (120)

500 (150)

 

 

 

 

 

 

 

 

 

1280 x 1024*

<250 (75)

>300 (90)

350 (105)

450 (135)

 

 

 

 

 

 

 

 

 

1360 x 765

<250 (75)

>300 (90)

400 (120)

500 (150)

 

 

 

 

 

 

 

 

 

1365 x 768

<250 (75)

>300 (90)

400 (120)

450 (135)

 

 

 

 

 

 

 

 

 

1366 x 768

<250 (75)

>300 (90)

400 (120)

450 (135)

 

 

 

 

 

 

 

 

 

1400 x 1050

<250 (75)

>300 (90)

350 (105)

400 (120)

 

 

 

 

 

 

 

 

 

1440 x 900

<250 (75)

>300 (90)

350 (105)

400 (120)

 

 

 

 

 

 

 

 

 

1600 x 1200*

<250 (75)

>300 (90)

300 (90)

450 (135)

 

 

 

 

 

 

 

 

 

1920 x 1200

<250 (75)

>300 (90)

300 (90)

400 (120)

 

 

 

 

 

 

 

 

 

2048 x 1080

<250 (75)

>300 (90)

300 (90)

400 (120)

 

 

 

 

 

 

 

 

 

HDTV 720p

<250 (75)

>300 (90)

400 (120)

500 (150)

 

 

 

 

 

 

 

 

 

HDTV 1080i

<250 (75)

>300 (90)

300 (90)

400 (120)

 

 

 

 

 

 

 

 

 

HDTV 1080p

<250 (75)

>300 (90)

300 (90)

400 (120)

 

 

 

 

 

 

 

 

*same spec at 75 Hz

Figure 6. Maximum Transmission Distances for Analog Signals at 60 Hz

fRS-232 connector (3-pole captive screw - MTP T 15HD RSA only) — Connect to this for bi- or unidirectional RS-232 communication. The RS-232 function is only available by setting the on-the-board DIP switch from audio to RS-232 communication. The default is audio.

See page 8 for setting the DIP switch.

gSkew, Peaking and Level LEDs (MTP R 15HD RSA SEQ only) — These three LEDs (red, green, and blue) are used to indicate the misaligned colors when adjusting the Skew Equalization settings. They are also used for identifying Peaking and Level modes when adjusting for signal loss or optimizing the image for various cable lengths. The LEDs are labelled: R =Red, G/L = Green/Level, B/P = Blue/Peaking

NOTES: Skew is the color misalignment present in twisted pair A/V systems using

Category 5, 5e, or 6 cable in which the red, green, and blue video signals

arrive at the display at different times.

Level alters the video output voltage to affect the brightness of the

displayed image.

Peaking affects the sharpness of a picture.

hSelect Button (MTP R 15HD RSA SEQ only) — This recessed button selects between, Skew Equalization, Level, and Peaking when adjustments are needed.

iRotary Adjust Knob (MTP R 15HD RSA SEQ only) — Within any function, rotate this Adjust knob to make the appropriate changes to the skew delay, level, or peaking.

PowerCage MTP T 15HD RSA and PowerCage MTP R 15HD RSA SEQ • Installation and Operation

7

Page 11
Image 11
Extron electronic MTP 15HD RSA manual Maximum Transmission Distances for Analog Signals at 60 Hz