MTP SW6 • Remote Contol
Remote Control, cont’d
3-12
MTP SW6 • Remote Contol
3-13
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Switch mode
Set normal (manual)
switch mode
1# F1]The user selects inputs manually, from the front panel or
under remote control.
Set auto switch mode 2# F2]The switcher automatically switches to the highest
numbered input with signals present. Manual switching
is disabled.
Lock (executive) modes
Lock front panel
functions
1X Exe1]Enable Lock mode 1.
Unlock front panel
functions
0X Exe0]Enable Lock mode 0.
View lock status X X1#]
Command/response table for SIS commands (continued)
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Resets
Reset all level and
peaking adjustments
EZT}Zpt]Clear all level and peaking adjustments to their default
(0) values.
Reset all skew
adjustments
EZK}Zpk]Clear all input and output skew values to 0 ns.
Reset audio input levels EZA}Zpa]Reset all audio input levels (gain and attenuation) to 0 dB.
Reset audio output level EZV}Zpv]Reset the audio output levels (volume) to 100% (no
attenuation).
Reset whole switcher EZXXX}Zpx]Clear all ties and presets, reset all audio gains to 0 dB,
and reset volume to 100%.
N X1# = Front panel lock 0 = off (unlocked)
1 = on (locked)