MTP SW6 • Remote Contol
Remote Control, cont’d
3-14
MTP SW6 • Remote Contol
3-15
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Information requests
Information request I VX!•AX!•FX1$•VmtX1#•AmtX1#•ExeX1#]
V (selected video input)•A (selected audio input)• F
(switch mode)•Vmt (video mute — not supported by this
switcher)•Amt (audio mute)•Exe (front panel lock).
Request part number N 68-928-01]See appendix A for part numbers.
Query controller
rmware version
QX1%]
Example: Q1.23]The factory-installed controller rmware version is 1.23
(sample value only).
Request system
threshold status
42S X$]
Command/response table for SIS commands (continued)
N X! = Input number
1 – 6
X1$ = Switch mode 1 = normal (manual)
2 = auto
X1# = Mute, Front panel lock 0 = off
1 = on
X1% = Firmware version v.vv
X$ = Threshold 0 = outside of threshold
Windows®-Based Program Control
The Windows-based Extron Universal Switcher Control
Program, which communicates with the switcher via the
Remote port, provides an easy way to congure and operate
the MTP SW6 switcher. The program is compatible with
Windows 2000 and Windows XP or higher versions.

Installing the software

The program is contained on the Extron Software Products
CD-ROM, disk B. Install the software as follows:
1. Insert the CD-ROM into the drive. The installation
program should start automatically. If it does not self-start,
run Launch.exe from the CD.
The Extron software CD window appears (gure 3-2).
Figure 3-2 — Software CD window
2. Click the Software tab (gure 3-2).
3. Scroll to the desired program and click Install (gure 3-3).
Figure 3-3 — Software installation