B&B Electronics HVD100A3 Master Reset Command, Byte, Function, Number, Value, Vendor Information

Models: HVD100A3

1 31
Download 31 pages 45.58 Kb
Page 15
Image 15
Master Reset Command

Master Reset Command

The master reset command allows the HDV100A3 to be reset from the PC. Sending this command resets the HDV100A3 to the default start-up state. You will lose all setting sent in the smart mode.

Byte

Byte

Function

Number

Value

 

1

01

Start of frame

2

04

Number of control bytes

3

08

ID byte 08 = internal command

4

08

Function code 08= master reset

5

01

Check byte

6

02

Check byte

7

00

Number data bytes

8

18

Checksum

Note: after sending a master reset the baud rate is 115,2k (default).

Vendor Information

To receive the vendor information from the HDV100A3 send hex (01, 01, 05, 00, 07) to the device. It will respond as follows:

Hex (01, 0B, 85, MM, DD, MA, M1, M2, MO, 00, VV, VV, 00, DB, CS)

0B = Number of control bytes

85 = Compatibility with other models

MM= Month firmware was created DD = Day firmware was created

MA = Major firmware revision number M1 = MSB of minor firmware revision M2 = LSB of firmware revision

MO = Model

VV = Customer code 1 VV = Customer code 2 DB = Number of data bytes CS = Checksum

HDV100A3 Command & Response Manual-1306cr

11

B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5104

Page 15