Setting Baud 1, Baud 2

Baud Rate Setup Table

Baud

Decimal

Hex Divisor MSB

Hex Divisor LSB

Rate

Divisor

(Baud 2)

(Baud 1)

9600

48

$00 (default)

$30 (default)

14400

32

$00

$20

19200

24

$00

$18

38,400

12

$00

$0C

57,600

8

$00

$08

115,200

4

$00

$04

230,400

2

$00

$02

460,800

1

$00

$01

All baud rates are entered as hex numbers. To calculate your own decimal divisor use the following formula. The decimal number must be converted to hexadecimal before entering the number. Baud rates below 9,600 are not recommended because of the difference in speed between the vehicle bus and PC serial port. Additionally, baud rates faster than 115,200 baud are not supported.

The UART clock = 7,372,800 Hz

Decimal Divisor = Clock frequency ( 7,372,800)

Baud output x 16

If you want a baud rate of 9,600 baud

Decimal Divisor = 7,372,800 9,600 x 16

Decimal Divisor = 48 = 30 hex

Baud 1= 30

Baud 2= 00

HDV100A3 Command & Response Manual-1306cr

7

B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5104

Page 11
Image 11
B&B Electronics HVD100A3 manual Setting Baud 1, Baud Baud Rate Setup Table