B&B Electronics HVD100A3 manual Baud Rate Example, Byte Function, Number, Value

Models: HVD100A3

1 31
Download 31 pages 45.58 Kb
Page 12
Image 12
Baud Rate Example

Baud Rate Example

To set the PC baud rate to 57,600 baud, N,8,1, format the message as follows.

Byte

Byte

 

Byte Function

 

Number

Value

 

 

 

 

 

 

Hex

 

 

 

1

01

 

Start of frame

 

2

05

 

Number of control bytes

 

3

08

 

Command byte (08 = internal command)

 

4

01

 

Function Bbte (01 = change baud)

 

5

03

 

UB3

 

6

08

 

Baud 1

 

7

00

 

Baud 2

 

8

00

 

Number of data bytes

 

9

1A

 

Checksum

 

The first byte is the start of frame and always 01. Next is the number of control bytes (05). There are 5 bytes in the control section (in gray). Byte number 3 sets the HDV100A3 to an internal operation (08). Byte 4 is the internal function to be executed; (01) is the change baud command. Bytes 5, 6, and 7 set the baud rate, parity, stop bits and word length. Next is the number of data bytes, in this case there are no data bytes. Last is the checksum, the value is the 8 bit addition of bytes 1 to 8.