After sending a transmit message to the HDV100A3 you will get the confirmation message if the checksum is correct. A transmit complete message is sent to the PC after the device successfully transmits the message to the J1708 bus. A second message should not be sent to the device before confirming that the first message has been sent. The transmit confirmation is formatted as follows:

Byte

Byte Value

Byte Function

Number

(hex)

 

1

01

Start of frame

2

01

Number of control bytes

3

09

ID bytes 9 = transmit OK

8

00

Number of data bytes

9

0B

Checksum