Error Codes

Error Codes

Error Code Format:

Byte Number

 

Byte Value

 

Function

 

 

 

 

 

 

 

1

 

 

01

 

Start of frame

 

2

 

 

03

 

Number of control bytes

 

3

 

 

05

 

Function code error = 05

 

4

 

 

XY

 

ID of message that caused error

 

5

 

 

0Z

 

Error code (see chart below)

 

6

 

 

00

 

Number of data bytes

 

7

 

 

CS

 

Checksum

 

 

 

 

 

Error Code

Type of Error

Meaning of Error Generated

 

 

Generated

 

 

 

DEC

HEX

 

 

 

 

 

1

1

Gen

Inbuffer overflow; more than 127 bytes

2

2

Gen

Checksum mismatch

3

3

Gen

Protocol error; function, ID, code bad

4

4

J1708

J1708 input buffer full missed bus message

5

5

J1708

J1708 command unknown

6

6

J1708

J1708 output buffer full

7

7

 

 

 

 

 

8

8

J1939

Bus off

9

9

 

 

 

 

 

10

A

J1708

J1708 inbuffer overflow more than 127 bytes

11

B

 

 

 

 

 

12

C

 

 

 

 

 

13

D

 

 

 

 

 

14

E

 

 

 

 

 

15

F

 

 

 

 

 