Arbitration Field (Y1, Y2, Y3, Y4)

Data messages received from the HDV100A3 operating in the J1939 mode, is formatted as follows:

Control Field

 

 

 

 

 

Data Field

 

 

 

Bus Data

 

Start

# of

Contr

Time Stamp

# of

Arbitration

# of

 

 

Check

of

Control

Byte

4 Bytes

Data

 

Field

Data

 

Up to 8 Bytes

sum

Frame

bytes

 

 

 

 

 

Bytes

 

 

 

 

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

 

 

 

 

 

 

 

 

01

05

02

msb

 

 

lsb

ZZ

Y1

Y2

Y3

Y4

0X

 

 

 

 

 

 

 

 

 

The message starts with 01. The number of control bytes is 05. Next is the control byte 02, followed by the time stamp, four bytes, with msb first. The number of data bytes is the number of bytes to follow excluding itself and the checksum byte. Next is a four byte that contains the arbitration field. J1939 divides this field for different functions show in the chart below. The number of data bytes sent by the bus is next. This will be a value between 0 and 8. Next is the bus data followed by the checksum byte.

Arbitration Field (Y1, Y2, Y3, Y4)

The first byte Y1 contains the most significant bits in the J1939 arbitration field. It is followed by Y2, Y3 and Y4. J1939 assigns different function to the arbitration field that must be observed by the user. There is a work sheet included on page 33 to help set up this field.

Arbitration Byte

Y1

 

 

 

 

 

 

Y2

 

 

 

 

 

Y3

 

 

 

Y4

 

 

 

 

 

 

Arbitration Bit

7

6

5

4

3

2

1

0

7

6

5

4

3

2

1

0

7

6

5

4

3

2

1

0

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1939 Arbitration Field

29

28

27

26

 

 

 

 

252423222120191817161514131211109

 

 

 

 

8

7

6

5

4

3

2

1

 

 

 

Bit Position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1939 Function

Priority

R

D

PDU Format

 

 

PDU Specific

Source Address

 

 

 

 

 

 

bits

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HDV100A3 Command & Response Manual-1306cr