B&B Electronics HVD100A3 manual Byte value, Byte Function, number

Models: HVD100A3

1 31
Download 31 pages 45.58 Kb
Page 17
Image 17
Byte value

Byte

Byte value

Byte Function

number

(hex)

 

1

01

Start of frame

2

02

The number of control bytes

3

01

ID byte 01= J1708

4

10

Function code 10 hex stop receive

5

00

Number of data bytes (00 place holder)

6

14

Checksum (bytes 1 through 5 added

 

 

together)

After sending this command to the device, the device will respond with a confirmation message and data will cease. Note that there is the possibility of an incomplete message being sent to the PC after sending this command. Use the check-sum to verify all messages.

To restart reception, send the (01, 02, 01, 11, 00, 15) command to the HDV.

HDV100A3 Command & Response Manual-1306cr

13

B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5104

Page 17
Image 17
B&B Electronics HVD100A3 manual Byte value, Byte Function, number