Byte 4 Values

To stop broadcast transmission it is not necessary to send the whole message. The message below will stop broadcast transmission.

 

Byte

 

Byte

 

Function

 

 

 

Number

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

01

 

 

Start of frame

 

 

 

2

 

02

 

 

Control bytes

 

 

 

3

 

01

 

 

ID byte 1 = J1708 message

 

4

 

07

 

 

Set broadcast 7 = On X = Time interval (see chart)

 

7

 

00

 

 

Data bytes

 

 

 

8

 

0B

 

Checksum

 

 

 

Byte 4 Values

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte

Time

 

 

 

 

Value

Value

 

 

 

 

07

 

Stop broadcast

 

 

 

 

17

 

.5 sec.

 

 

 

 

27

 

1.0 sec

 

 

 

 

37

 

1.5 sec

 

 

 

 

47

 

2.0 sec

 

 

 

 

Byte 6 (Priority) Values

 

 

 

 

 

 

 

 

 

 

Byte Value

 

 

Byte Value

Priority

 

 

(hex)

 

 

Binary

 

 

 

 

 

 

 

 

 

 

 

 

01

 

 

 

00000001

 

1

 

 

02

 

 

 

00000010

 

2

 

 

04

 

 

 

00000100

 

3

 

 

08

 

 

 

00001000

 

4

 

 

10

 

 

 

00010000

 

5

 

 

20

 

 

 

00100000

 

6

 

 

40

 

 

 

01000000

 

7

 

 

80

 

 

 

10000000

 