MTP SW6 • Remote Contol
Remote Control, cont’d
3-8
MTP SW6 • Remote Contol
3-9
Command/response table for SIS commands (continued)
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Skew adjustment
Set all skew adjustment
values for an input
EX!*X%*X%*X%Iseq}
Set a specic skew adjustment for the TP input. X%
values are listed in RGB order.
IseqX!*X%*X%*X%]
Example: E2*0*0*4Iseq}Iseq02*00*00*04]Set input 2’s skew settings as follows:
Red = 0 ns
Green = 0 ns
Blue = 8 ns (delayed 8 ns).
Increment one input's
skew adjustment value
EX!*X^+Iseq}IseqX!*X%*X%*X%] Increase input X!'s X^ plane’s skew adjustment by 1 step
(2 ns).
Decrement one input's
skew adjustment value
EX!*X^-Iseq}IseqX!*X%*X%*X%] Decrease input X!'s X^ plane’s skew adjustment by
1 step (2 ns).
Example: E2*2*-Iseq}Iseq02*00*00*03]Decrease input 2’s blue skew by 2 ns to 6 ns.
Read input skew
adjustment values
EX!Iseq} X%*X%*X%]
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional description
RS-232 insert enable
Disable the RS-232 insert E1*0Lrpt}Lrpt0]Disable the RS-232 insert.
Enable the RS-232 insert E1*1Lrpt}Lrpt1]Enable the RS-232 insert.
Read the RS-232 insert
status
E1Lrpt} X&] Show the status of the RS-232 insert.
Audio/RS-232 TP input (wire pair 3 and 6) configuration
N The RS-232 insert, when enabled (E1*1Lrpt}), overrides the audio/RS-232 TP input configurations.
Congure input as
audio
X!*0\ TypX!*0]Dene the audio/RS-232 input as audio, such as
provided by an MTP 15HD A transmitter.
Congure input as
RS-232
X!*1\ TypX!*1]Dene the audio/RS-232 input as bidirectional serial
communications, such as provided by an MTP 15HD RS
transmitter.
Read TP input
conguration
X!\X*] Show the audio/RS-232 wire pair input denition.
N X! = Input number
1 – 6
X% = Skew adjustment range 00 – 31 (each step = 2ns)
X^ = Video plane 0 = red
1 = green
2 = blue
Command/response table for SIS commands (continued)
N X& = RS-232 output insert status 0 = disabled
1 = enabled
X! = Input number
1 – 6
X* = Audio/RS-232 wire pair input type 0 = audio
1 = RS-232