3-

Command/response table for SIS commands (continued)

8

 

 

 

 

 

 

 

 

 

 

 

Command

ASCII Command

Response

Additional description

MTP

 

(host to unit)

 

(unit to host)

 

 

Skew adjustment

 

 

 

 

SW6

Set all skew adjustment

EX!*X%*X%*X%Iseq}

 

Set a specific skew adjustment for the TP input. X%

values for an input

E2*0*0*4Iseq}

 

IseqX!*X%*X%*X%]

values are listed in RGB order.

Example:

 

Iseq02*00*00*04]

Set input 2’s skew settings as follows:

Remote

 

 

 

 

Blue = 8 ns (delayed 8 ns).

 

 

 

 

 

Red = 0 ns

 

 

 

 

 

Green = 0 ns

Control

Increment one input's

EX!*X^+Iseq}

IseqX!*X%*X%*X%]

Increase input X!'s X^plane’s skew adjustment by 1 step

Decrement one input's

EX!*X^-Iseq}

 

IseqX!*X%*X%*X%]

Decrease input X!'s X^plane’s skew adjustment by

 

skew adjustment value

 

 

 

(2 ns).

 

skew adjustment value

 

 

 

1 step (2 ns).

 

Example:

E2*2*-Iseq}

 

Iseq02*00*00*03]

Decrease input 2’s blue skew by 2 ns to 6 ns.

 

Read input skew

EX!Iseq}

 

X%*X%*X%]

 

 

adjustment values

 

 

 

 

 

 

 

 

 

 

N X!= Input number

1 – 6

 

 

 

X%= Skew adjustment range

00 – 31 (each step = 2ns)

 

 

X^= Video plane

 

0 = red

 

 

1 = green

2 = blue

Command/response table for SIS commands (continued)

Command

ASCII Command

Response

Additional description

 

(host to unit)

(unit to host)

 

RS-232 insert enable

 

 

 

Disable the RS-232 insert

E1*0Lrpt}

Lrpt0]

Disable the RS-232 insert.

Enable the RS-232 insert

E1*1Lrpt}

Lrpt1]

Enable the RS-232 insert.

Read the RS-232 insert

E1Lrpt}

X&]

Show the status of the RS-232 insert.

status

 

 

 

Audio/RS-232 TP input (wire pair 3 and 6) configuration

NThe RS-232 insert, when enabled (E1*1Lrpt}), overrides the audio/RS-232 TP input configurations.

 

Configure input as

X!*0\

TypX!*0]

Define the audio/RS-232 input as audio, such as

 

audio

 

 

 

provided by an MTP 15HD A transmitter.

MTP

Configure input as

X!*1\

TypX!*1]

Define the audio/RS-232 input as bidirectional serial

RS-232

 

 

 

communications, such as provided by an MTP 15HD RS

 

 

 

 

transmitter.

SW6

Read TP input

X!\

X*]

Show the audio/RS-232 wire pair input definition.

configuration

 

 

 

 

 

 

 

 

 

Remote

N X&= RS-232 output insert status

0

= disabled

 

X!= Input number

1

= enabled

 

1 – 6

 

X*= Audio/RS-232 wire pair input type

0

= audio

 

Control

 

 

 

1

= RS-232

 

 

 

 

 

 

3-9

 

 

 

 

 

Remote Control, cont’d

Page 22
Image 22
Extron electronic MTP SW6 Skew adjustment, RS-232 insert enable, Audio/RS-232 TP input wire pair 3 and 6 configuration